نتایج جستجو برای: treatment planning system

تعداد نتایج: 3598653  

Journal: :journal of biomedical physics and engineering 0
s sina radiation research center, shiraz university, shiraz, iran r faghihi a s meigooni

background: most of the current brachytherapy treatment planning systems (tps) use the tg-43u1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects. objective: the purpose of this study is developing a method for obtaining correction factors for heterogeneity for cs-137 brachytherapy sources based on pre-calculated mc simulations and interpolation. method: t...

Journal: :journal of biomedical physics and engineering 0
m oshaghi master student, department of biomedical engineering, science and research branch, islamic azad university, tehran, iran m sadeghi associate, agricultural, medical & industrial research school, nuclear science and technology research institute, karaj, tehran, iran sr mahdavi assistant professor of medical physics, department of medical physics, faculty of medicine, tehran university of medical sciences, tehran, iran ar shirazi

background: accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and lung doses are correlated with toxicity in patients treated with breast brachytherapy. objective: to investigate the percentage of the dose received by critical organ (skin), thermoluminescence dete...

Journal: :iranian journal of radiation research 0
m. akram department of physics, the islamia university of bahawalpur pakistan k. iqbal department of physics, the islamia university of bahawalpur pakistan m. isa department of physics, the islamia university of bahawalpur pakistan m. afzal department of physics, the islamia university of bahawalpur pakistan s.a. buzdar department of physics, the islamia university of bahawalpur pakistan

background: it was intended to investigate the effect of physical wedge (pw) and enhanced dynamic wedges (edw) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. materials and methods: the varian’s clinac dual mode linear accelerator model 2100 c/d and siemen’s primus accelerators were used for radiation doses with 6 mv and ...

Mahdi Jamali Mahdi Mommennezhad Shahrokh Naseri Tahereh yazdpour parizi

Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...

Journal: :Journal of Cancer Prevention & Current Research 2016

A S Meigooni R Faghihi S Sina,

Background: Most of the current brachytherapy treatment planning systems (TPS) use the TG-43U1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects.Objective: The purpose of this study is developing a method for obtaining correction factors for heterogeneity for Cs-137 brachytherapy sources based on pre-calculated MC simulations and interpolation.Method: To ...

Journal: :journal of medical signals and sensors 0

an important need in radiation therapy is a fast and accurate treatment planning system. this system using ct data and characteristics of the radiation beam, calculates the dose in all points of the patient’s volume. two main factors in planning system are “accuracy” and “speed”. according to these factors, various generation of treatment planning systems are developed.   this article is the re...

Journal: :iranian journal of radiation research 0
m.n. anjum a. qadir m. afzal

background: the dosimetric performance of eclipse 6.5 three dimensional treatment planning system (3dtps) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of american association for physicists in medicine task group 53. materials and methods: the calculations were performed by the 3dtps for symmetric as well as asymmetric fields for standar...

Journal: :iranian journal of medical physics 0
hossein salehi yazdi m.sc. student of medical radiation engineering , nuclear engineering and physics dept., amirkabir university of technology, tehran, iran mojtaba shamsaei assistant professor, nuclear engineering and physics dept., amirkabir university of technology, tehran, iran hamid reza shabani m.sc. student of medical physics, medical physics dept., tehran university of medical sciences, tehran, iran ramin jaberi radiotherapy physicist, cancer institute, imam khomeini hospital, tehran, iran saeed setayeshi associate professor, nuclear engineering and physics dept., amirkabir university of technology, tehran, iran

introduction: this study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (tps) for 192ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. materials and methods: a ct scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...

Journal: :Journal of Applied Clinical Medical Physics 2015

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید